能量计EIT Power Map
首页加入收藏
能量计EIT Power Map
销售热线:15999953844 18023745066 18078808824

首页 关于众宇旺 仪器类目 仪器品牌 仪器资讯 仪器文章 促销专区 联系我们 访客留言
环境测量 分析仪器 气体检测 电力仪器 电子电工 无损检测 通讯测试 测绘仪器 工具仪器 其它仪器
 
首页仪器目录分析仪器UV能量计 → 能量计EIT Power Map
 能量计EIT Power Map
仪器名称 能量计EIT Power Map
产品品牌 美国EIT
所属类别 分析仪器 | UV能量计
产品型号EIT Power Map
生产厂家美国EIT
优惠热线15999953844 18023745066 18078808824
在线咨询
 能量计EIT Power Map简要介绍
测量并且图解的UV光强表示为时间的函数(W/cm2);UV PowerMAP可同时测量4个光波段的UV能量密度(J/cm2),UV Map Plus只能测量一个光波段;
 能量计EIT Power Map详细介绍

测量并且图解的UV光强表示为时间的函数(W/cm2);UV PowerMAP可同时测量4个光波段的UV能量密度(J/cm2),UV Map Plus只能测量一个光波段;
检测系统的焦距,监测产品使用环境温度状况;
比较多个灯的特征;
比较单个UV系统在不同时间的表现,或者比较不同系统;
使用PowerView软件查看、分析、操作、储存数据数据以图表方式显示和储存)

Features (Benefits) :-

Application :-



Introduction

EIT's UV PowerMAP and UV MAP Plus are advanced measurement systems that measure and store UV energy, UV irradiance, and temperature information derived from their optics and thermocouple probes in UV curing processes. The UV PowerMAP simultaneously measures all four UV channels while the UV MAP Plus measures one channel.

The information is transferred to a PC where it is presented in graph and data format for viewing and analysis. The information is characteristic of the same energy and irradiance that would be impinged on an actual work piece passing through the curing process.

PowerView software
The UV PowerMAP and the UV MAP Plus are the ultimate tools for developing, monitoring, and maintaining UV curing processes. UV formulators, raw material suppliers, and equipment suppliers can take advantage of the UV PowerMAP's ability to measure all four UV channels to develop processes that are easily transferred from a laboratory to a production environment. The UV MAP Plus monitors the one UV channel specified (A, B, C, or V) when it is ordered. The UV MAP Plus was designed more for use on a production floor, and it is an economical alternative to the UV PowerMAP. With the PowerView software, the UV PowerMAP and the UV MAP Plus offer far greater resolution, data sampling, data storage, and data manipulation than previously available in mapping systems.

Variables such as reflector materials, reflector shapes, wavelength-specific reflector degradation and uniformity, and lamp focus can be documented. Companies using multi-lamp curing systems and those that are using different spectral lamps within a system will find these radiometers indispensable.

The UV PowerMAP and UV MAP Plus systems are composed of a data collection unit, detachable optic measurement head, and PowerView software package. The units measure UV energy in Joules/cm2 and UV irradiance in Watts/cm2. With PowerView, UV sample rates are adjusted from 128 to 2048 samples per second to match resolution and information requirements.

Setup View
PowerView uploads and displays the collected UV system data, unit configurations, and time/date stamps. This data is saved as a computer file that can be manipulated, customized, and exported into a spreadsheet by the user so the entire UV system can be evaluated.

Operation

The UV PowerMAP and UV MAP Plus are initially configured at the factory before they are shipped. Settings are easily viewed and changed in a Setup screen in PowerView. In Setup, the user can set the unit's configuration to best match the lamp system and get the desired data. The channels that are enabled, the time and date settings, port settings, and the UV sample rate are easily changed with the click of a mouse. The unit's maximum sample rate of 2048 samples/second and its ability to store up to I million data points ensures accurate and sharp resolution - even at high speeds.

The user inserts the unit into a stationary or conveyorized UV process for data collection in the same manner that an actual work piece would be inserted. The unit's low, narrow profile of only 0.5"H x 3.5"W allows usage in a wide range of demanding physical environments. The unit's optics are offset so it can collect data at the ends of the bulbs where lamp degradation tends to occur first.

Transfer View
Upon exiting from the curing environment, the unit is connected to a PC serial port via cable so that the "run" information can be uploaded into the PowerView application software.

The data transfer is initiated in PowerView's Transfer View screen, where the unit configuration and transfer progress are displayed. The user can enter information such as line speed, amp readings, lamp settings, types of bulbs, and any other information relevant to the run. The user can also see a preliminary view of the plot. A detailed look at the plot is available after the transfer is complete.

PowerView shows the status of a curing system in a clear, easy to read format. The user can see which lamps and reflectors in a system are well focused and performing most efficiently. PowerView's ability to compare two different runs is one of its most important features. The run data files are referred to as a "Sample" file and a "Reference" file.

Graph View
PowerView's Graph View screen shows the UV irradiance and temperature data for the runs in graphical form. The user can toggle the display of the temperature and any of the UV channels (for PowerMAP) either on or off. Graph View has a zoom feature to enlarge any portion of the plot, and cursor measurement for detailed analysis. The user can change the appearance or color of a curve, and a data-smoothing filter is available to improve plot viewing.

The Data View screen lists the total energy density (J/cm2) and the peak power density (W/cm2) for each active spectral channel. The average temperature and peak temperature readings collected by the thermocouple are also presented. If two files are open, Data View shows the differences between readings as absolute values and as percentages. Logged information and user-entered information is also displayed for both run files.

Data View
A Type J thermocouple probe is used for substrate temperature measurement. Temperatures from 0° to 500°C are recorded at 32 samples per second. This is an important function if curing is taking place on temperature sensitive substrates.

An over-temperature alarm alerts the user when the unit's internal temperature exceeds 65°C. This gives the user time to remove the unit from a thermally hostile environment before it overheats.

The UV PowerMAP and the UV MAP Plus are powered by nickel metal hydride (NiMH) batteries, which can be recharged approximately 500 times before needing replacement. An audible alarm sounds when the batteries need recharging.

Routine maintenance for the units consists of battery charging, cleaning, and returning the optics heads for routine calibration. Recharging is accomplished by a one-hour "quick" charge.

Keeping the optics clean is essential for getting proper measurement results, and it requires only cotton swabs and acetone. The case can be cleaned with isopropyl alcohol and a soft cloth.

Since the optics head disconnects from the DCU, only the optics head has to be returned for periodic calibration. It is connected to the collection unit by two mechanical pins and a row of electrical contacts, and locked into place by two setscrews. Another optics head may be purchased to avoid down time during recalibration or to upgrade from single to four-channel capability.

Summary

The UV PowerMAP and the UV MAP Plus have an enormous advantage over other UV measurement instruments on the market. Both allow the user to evaluate the entire lamp system to see how well it delivers UV light to the actual cure surface. Focused lamp systems with good reflectors typically cure more efficiently which is important considering that as much as 75% of the energy reaching the cure surface is reelected energy.

The collected data allows the user to adjust the curing process to ensure that the UV system is operating at maximum efficiency.

The data that is graphed can be archived for future reference or printed and attached to work orders for ISO or FDA audits. The historical data can be used to make comparisons between current runs and previous runs. UV lamps within a system can be compared to each other, or entirely different UV systems can be analyzed and compared.

能量计EIT Power Map相关仪器 更多...

能量计EIT Power Map
美国EIT

标准UV能量计UV- Integrator 14
德国DESIGN

UV能量计UV 7011-A
美国EIT

UV能量计uv-int160
德国DESIGN

单波段UV能量计 EIT UVICURE PLUS
美国EIT

四通道UV能量计EIT Power Puck
美国EIT

UV能量计UV3-T-SD
德国DESIGN

能量计UV-351
日本ORC
UV能量计关键词:
UV能量计品牌
德国DESIGN 美国EIT
日本ORC

UV能量计同品牌仪器
·能量计EIT Power Map..
·UV能量计UV 7011-A
·单波段UV能量计 EIT UVICURE P..
·四通道UV能量计EIT Power Puck..
·迷你UV能量计MICROCURE..

UV能量计最新关注
·迷你UV能量计MICROCURE..
·UV能量计UV-M06
·能量计UV-M03A
·能量计UV-351
·UV能量计UV-M10
·UV能量计UV3-T-SD
·四通道UV能量计EIT Power Puck..
·单波段UV能量计 EIT UVICURE P..
·UV能量计uv-int160
·UV能量计UV 7011-A
最新关注
主推仪器温度计 红外线测温仪 温湿度表 风速计 照度计 紫外线强度计 可燃性气体检测仪 氧气分析仪 烟气分析仪 二氧化碳分析仪 万用表 示波器 电池测试仪 电力分析仪 电缆故障定位仪 钳表 硬度计 场强仪 高斯计 酸度计 工业工具 噪音计 亮度计 电阻测试仪 记录仪 汽车尾气分析仪(烟度计) 套装组合工具 尘埃粒子计数器
关于我们 | 联系我们 | 仪器类目 | 仪器品牌 | 促销信息 | 在线咨询
销售电话:15999953844 18023745066 18078808824 传真:020-66639949-888(自动传真) E_mail:sales@3n17.com
877082042 916611353 1329459311 1057763045 530706710
公司地址:广州市天河区龙洞北庆里2号 邮编:510520
能量计EIT Power Map
分类地图 品牌地图 关键字地图 环境测量 分析仪器 气体检测 电力仪器 电子电工 无损检测 通讯测试 测绘仪器 工具仪器 其它仪器
Copyright 2009 3n17.com All Rights Reserved. 广州众宇旺电子科技有限公司 版权所有